Con Edison 867 Product Transfer and Resale Report
Con Edison · X12 4010
The Con Edison 867 is the product transfer and resale report sent to report goods sold or transferred.
Con Edison’s published 867 specification, rendered as an interactive guide. Expand any segment to see its elements, data types, lengths and accepted codes — then validate your own document against it below.
Specification
13 of 13 segments
HEADING
ST
Transaction Set Header
pos 010
Required
max —
BPT
Beginning Segment for Product Transfer and Resale
For cancellations of previously reported usage, Con Edison sends a separate transaction containing the cancelled usage.
pos 020
Required
max —
DTM
Date/Time Reference
Con Edison will always provide the date of the customer's next scheduled meter read.
pos 050
Required
max —
REF
Reference Identification
Not used at Con Edison on 867 Monthly Usage Transactions (ESCO/Marketer Customer Account Number).
pos 060
Optional
max —
N1 Looprequired
N1
Name
On 867 Monthly Usage Transactions, Con Edison provides the E/M Name as it appears in Con Edison files, and separately the Customer Name as it appears on the Con Edison account.
pos 080
Required
max —
N3
Address Information
Service address will be provided at Con Edison on 867 Monthly Usage Transactions.
pos 100
Required
max —
N4
Geographic Location
Service address (geographic location) will be provided at Con Edison on 867 Monthly Usage Transactions.
pos 110
Required
max —
REF
Reference Identification
Con Edison will provide the Previous Utility Account Number on 867 Monthly Usage Transactions, where the account number has changed in the last 90 days.
pos 120
Optional
max —
DETAIL
PTD Looprequired
PTD
Product Transfer and Resale Detail
At Con Edison, on 867 Monthly Usage Transactions the PTD-BO loop (Metered Summary) is used for all accounts with metered services and contains the summary usage information for the account, including Time of Use billing measurements for kilowatthours and/or demand that are not associated with specific meters. Time of Use accounts can be identified via the Time of Use codes listed in REF (Rate Sub Class) as well as service class 116, 117, or 118; descriptions available via Con Edison's Retail Access Website at http://www.coned.com/retailaccess. Additionally, on 867 Monthly Usage Responses, the PTD-BC loop (Unmetered Usage) is sent when the account has unmetered service points, and contains the unmetered usage history data for the account.
pos 010
Required
max —
REF
Reference Identification
On 867 Monthly Usage Transactions, Con Edison sends the Rate Sub Class in the BO, BC, and BQ PTD loops for electric accounts only; not used for monthly usage of gas accounts. Used to indicate whether the account is High or Low Tension or Both, a DC (direct current) indicator where 'Y' means DC and 'N' means AC, and a two digit Time of Use code. Format: HI or LO or BO, space, Y or N, space, two-digit Time of Day Code (e.g., 'HI N 54' = high tension AC, Time of Day Code 54). Time of Day Code descriptions available via Con Edison's Retail Access Website at http://www.coned.com/retailaccess.
pos 030
Optional
max —
AMT
Monetary Amount
Not used at Con Edison on 867 Monthly Usage Transactions (Backout Credit).
pos 140
Optional
max —
MEA
Measurements
At Con Edison, additional Measurement Significance Codes are needed to correctly describe electric usage, used in 867 Electric Historical Usage Responses.
pos 160
Optional
max —
SUMMARY
SE
Transaction Set Trailer
pos 030
Required
max —
Validate your 867
Paste or upload a document and check it against Con Edison’s published rules — segment order and repetition, required elements, field lengths, data types and accepted codes. Nothing is stored.
Go live on Con Edison’s 867 in days, not months
Connect this guide to your accounting system and test with Con Edison yourself, or leave the mapping and the test cycle to us, at no extra charge.